Do not turn over the unit without shock absorber during pull out the piping. It may cause intake grille damage.
Use shock absorber during pull out the piping to protect the intake grille from damage.
Cover for the right piping
Cover for the bottom piping
Cover for the left piping
Step 2Install the Indoor Unit
Hook the indoor unit onto the upper portion of installation plate.
(Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving it in left and right.
Indoor unit
Holder
Sleeve for piping hole
Piping
Drain hose
There is an option to use the holder at the rear of chassis to prop up the indoor unit as shown in the illustration for ease of installation. Push the holder back to original position before secure the indoor unit.
Press the area of orange color to release holder.
3/4 ~ 1.75HP: 1 holder 2.0 ~ 2.5HP: 2 holders
Alternatively, bottom plate of the indoor unit can be removed to enlarge the space for installation. Please refer column “How to take out front grille”.
Step 3Secure the Indoor Unit
Press the lower left and right side of the unit against the installation plate until hooks engages with their slot (sound click).
Unit’s hook
Installation plate
Step 4Insert the power supply cord and connection cable
Insert the cables from bottom of the unit through the control board hole until terminal board area.